Bolted Bonnet · Rising Stem · Resilient Wedge · Flanged x Groove and Groove x Groove 250Psi/300Psi/17.2 bar/20.7 bar Non shock cold working pressure Confirms to AWWA C509 Coating-Electrostatically applied fusion bonded epoxy coated 0.2 – 0.5 mm inside and outside. Maximum operating temperature 160°F/ 71°C Size range 2.5” to 12”- 300 PSI and 12” to 16” – 250 PSI UL Listed FM Approved
The Grooved End & Wafer type Butterfly valves are indicating type designed for use in fire protection systems where a visual indication is required as to whether the valve is open or closed. They are used, for example, as system, sectional, and pump water control valves. They have cut groove inlet and outlet connectionsthat are suitable for use with grooved end pipe couplings that are listed and approved for fire protection systems.
Bolted Bonnet · Non-Rising Stem · Resilient Wedge ·
Flanged x Groove and Groove x Groove
250Psi/300Psi/17.2 bar/20.7 bar Non shock cold working pressure
Confirms to AWWA C509
Coating-Electrostatically applied fusion bonded epoxy 0.2 – 0.5 mm inside and outside.
Maximum operating temperature 160°F / 71°C
Size range 2.5” to 12”- 300 PSI and 12” to 16” – 250 PSI
UL Listed FM Approved
Fireguard TESTANDRAIN is a 300 PSI rated single handle ball valve that was specifically designed to provide both the test function and the express drain function required for a wet fire sprinkler system. It features a tamper resistant test orifice, integral tamper resistant sight glasses, and a tapped port for system access. Fireguard TESTANDRAIN meets all the requirements of NFPA-13, NFPA-13R, and NFPA-13D. Available in 1", 1-1/4" and 2" sizes in both NPT and BSPT
The FA003U/FA004U Standard/Quick Response Upright and FA005P/FA006P Standard/Quick Response Pendent Sprinklers (Ref. Figure A) are automatic sprinklers of the frangible bulb type. They are “standard/quick response – standard orifice spray sprinkler” intended for use in fire sprinkler systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on NFPA 13 requirements). The Upright, Pendent Sprinklers all produce a hemispherical water distribution pattern below the deflector.
Fireguard pumps are designed to provide water to Stand pipe, Sprinkler and Hydrant systems for Fire suppression in Industrial and commercial facilities. Fireguard pumps are design and manufacture together with advanced testing and accreditation to ensure the utmost in equipment reliability. All interior bolt or screw that are exposed to pumped liquid shall be of rolled bronze or corrosion resistant material
Alarm Valve is a double seated clapper check valve with grooved seat design, which ensures positive water flow for alarm operation and is designed for installation in wet pipe sprinkler system. External bypass prevents false alarm under all supply pressure condition. In the event of variable pressure condition, false alarm is prevented with the provision of retard chamber, thus the design allows for installation under both variable and constant supply pressure condition.
Fireguard produces various types fire fighting hoses with high quality for most demanding situations. All hoses are manufactured according to BS 6391-1983 TYPE 3. The Fireguard Advance rubber covered fire hose is the no. 1 choice for firefighters worldwide. This hose features: tough durable and abrasion resistant, resistance to oil, fuel and a wide range of chemicals, resistance to heat, UV and ozone, has excellent adhesion between rubber and textile, no cleaning and drying is required and easy to repair.